| Model | Description | Application |
|---|
| AM-805 | - Foot Monitor
- Utilizes 3 high sensitivity pancake detectors to detect most common radioactive materials used in laboratories Good sensitivity to C14
- Built-in film holder to prevent detector contamination
| - High sensitivity foot monitor for most common radioactive material very good sensitivity to C14, P32, P33, Cs 137 Operates with Model RML-200 or most Portable Ratemeters w/900vdc
|
| GP-200 (CE) | - END WINDOW GM
- 1.6 mg/cm2 Window
- Good Sensitivity to 14C, 32P, 35S & 137CS Contamination
- Good Gamma Dose
- .1 MeV to 1.5 MeV-BNC Connector
| - General Purpose Alpha, Beta, Gamma Contamination Monitoring 200 mR/hr Gamma Dose Monitoring (Based on 137Cs calibration)
|
| HP-265 (CE) | - PANCAKE GM
- 1.6 mg/cm2 Window
- Good Sensitivity to 14C, 32P, 35S & 137CS Contamination
- Good Gamma Dose
- .1 MeV to 1.5 MeV-BNC Connector
| - General Purpose Alpha, Beta, Gamma Contamination Monitoring 200 mR/hr Gamma Dose Monitoring (Based on 137Cs calibration)
|
| PPA-2T | - PANCAKE GM
- 1.6 mg/cm2 Window w/Tungsten Back Shield
- Best Sensitivity to 14C, 32P, 35S & 137CS Contamination
- BNC Connector
| - Lowest Background
- Excellent General Purpose Gamma Contamination
|
| GP-1001 (CE) | - CYLINDER GM
- Energy Compensated
- 40 keV-1.5 MeV ±15% Gamma Dose Range
- 0-200 mR/hr Gamma Dose
- BNC Connector
| - Energy compensated to 200 mR/hr
|
| GP-1002 (CE) | - CYLINDER GM
- Energy Compensated
- 40 keV-1.5 MeV ±15% Gamma Dose Range
- 0-1000 mR/hr Gamma Dose
- BNC Connector
| - Energy compensated to 1000 mR/hr
|
| GP-1003 (CE) | - CYLINDER GM
- Energy Compensated
- 40 keV-1.5 MeV ±15% Gamma Dose Range
- 0-10,000 mR/hr (10R/hr) Gamma Dose
- BNC Connector
| - Energy compensated to 10,000 mR/hr (10R/hr)
|
| GP-1010 (CE) | - GENERAL PURPOSE GAMMA/BETA W/ROTATING BETA WINDOW
- Energy Dependant
- 60 KeV-2 MeV Gamma-200 Mr/hr max.
- 200KeV Beta Minimum
| - Good general purpose detector to measure most common gamma and many common beta emitters. Rotating beta shield lets operator differentiate between gamma and beta.
|
| GLE-1 (CE) | - LOW ENERGY GAMMA SCINTILLATION
- Best for Iodine 125 & other Low Energy Gamma Contamination
- 1" X 2 mm Crystal w/7 mg/cm2 Window
- Magnetically Shielded BNC Connector
| - Most Sensitive I-125 Monitor
- Excellent Low Energy Gamma Monitoring (Cannot be dose calibrated)
|
| GSP-1 (CE) | - 1" x 1" GAMMA SCINTILLATION
- 35 mg/cm2Window
- Magnetically Shielded & Shock Mounted Background
- Approx. 200 CPM/µR/hr
- Magnetically Shielded - BNC Connector
| - General Purpose Gamma Contamination & Spectroscopy Monitoring
|
| GSP-2 (CE) | - 2" x 2" GAMMA SCINTILLATION
- 35 mg/cm2Window
- Magnetically Shielded & Shock Mounted Background
- Approximately 200 CPM/µR/hr w/900 VDC
- Magnetically Shielded - BNC Connector
| - General Purpose Gamma Contamination & Spectroscopy Monitoring
|
| ASP-2A (CE) | - 2" x ALPHA SCINTILLATION
- 0.5 mg/cm2Window
- Magnetically Shielded & Shock Mounted
- Low Background
- BNC Connector
| - High Sensitivity to Alpha Contamination 40+% Efficiency to Americium 241
|
| MRSP-1 (CE) | - Excellent tissue equivalent micro R gamma detector.
| - Good energy response from 15 keV to 2 MeV. Dose calibration based on 137Cs.
|